Av RECEIVER/AV AMPLIFIER
X-V463/HTR-61 40/

DSP-AX463

SERVICE MANUAL

IMPORTANT NOTICE

This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.
It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already
known and understood by the users, and have therefore not been restated.

WARNING: Failure to follow appropriate service and safety procedures when servicing this product may result in personal
injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons,
We advise all YAMAHA product owners that any service required should he performed by an authorized
YAMAHA Retailer or the appointed service representative.
IMPORTANT: The presentation or sale of this manual to any individual or firm does not constitute authorization. certification or
recognition of any applicable technical capabilities, or establish a principleragent relationship of any form.

3
5
SE
a:
TQ
>3:
:3
8e
a
O
\

The data provided is believed to be accurate and applicable to the unit(s) indicated on the Cover. The research, engineering, and
service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitable
and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please
contact the distributors Service Division.

WARNING: Static discharges can destroy expensive components. Discharge any static electricity your body may have
accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss).
IMPORTANT: Turn the unit OFF during disassembly and pan replacement. Recheck all work before you apply power to the unit.

I CONTENTS


To SERVICE PERSONNEL 2 DISPLAY DATA .. 4s
FRONT PANELS 3-4 IC DATA 47-61
REAR PANELS 5-9 BLOCK DIAGRAMS 63-67
REMOTE CONTROL PANELS 9 PRINTED CIRCUIT BOARDS.. 68-81
SPECIFICATIONS I 5%Iiii 10-12 PIN CONNECTION DIAGRAMS 82-83
INTERNAL VIEW 13 SCHEMATIc DIAGRAMS 85-98
DISASSEMBLY PROCEDURES I Mfilte. 14-16 REPLACEMENT PARTS LIST 99-117
UPDATING FIRMWARE / REMOTE CONTROL. 118-120
7 7-.Lx'7 I7®§3£$H 17-19 ADVANCED SETUP/

SELF-DIAGNOSTIC FUNCTION / 7 In»; May l~7v7"x :n-as'iité. 121
5M 77 (E EsaWififiE) . 20-45

LoviEx7:a77m;, I j 777aiw§iifififiéifi LTLiTa
This Service Manual uses recycled paper.

Thls manual is copyrighted by VAMAHA and may not be copied or

redistributed eilher in print or electronically Without permission. YAMAHA CORPORATlON

P.O.Box 1, Hamamatsu, Japan
g '03.03

1 0 1 0 8 5 D 2008 YAMAHA CORPORATION All nghts reserved.

Page 2

DSP-AX463

\
O
a,
E
,_
I
c
(3
(D
>.
X
n:

RX-V463/HTR-6140/DSP-AX463

I TO SERVICE PERSONNEL

1. Critical Components Information
Components having special characteristics are marked at and
must be replaced with parts having specifications equal to those
originally installed.

2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.

0 Meter impedance should be equivalent to 1500 ohms shunted
by 0.1 SpF.

For U model
E9 CAUTION

AC LEAKAGE
WALL EQUIPMENT TESTER OR
OUTLET UNDER TEST EQUIVALENT

®:D-

J;-

INSULATING
TABLE

0 Leakage current must not exceed 0.5mA.

0 Be sure to test for leakage with the AC plug in both polarities.

iAiv F3401: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 6A,

125V FUSE."

For C model
CAUTION

F3401: REPLACE WITH SAME TYPE 6A, 125V FUSE.

A'I'I'ENTION

F3401: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 6A,125V.

WARNING: CHEMICAL CONTENT NOTICE!

This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive

harm.

DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY

REASON WHAT SO EVER!

Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose

eyes to solder/flux vapor!

If you come in contact with solder or components located inside the enclosure of this product, wash your hands before

handling food.

About lead free solder / mfifil \ / 9173M, \ T

All of the P.C.B.s installed in this unit and solder joints are
soldered using the lead free solder.

Among some types of lead free solder currently available,
it is recommended to use one of the following types for the
repair work.

- Sn + Ag + Cu (tin + silver + copper)
- Sn + Cu (tin + copper)
- Sn + Zn + Bi (tin + Zinc + bismuth)

Caution:
As the melting point temperature of the lead free solder is
about 30°C to 40°C (50"F to 70°F) higher than that of the lead
solder, be sure to use a soldering iron suitable to each solder.

$filli§§éhtbté§NI®§tfifi$01\jS/lfibllckéififi
fifilafififid/ \JSE/ \JJlfibéfltbtiio

313.1%} \ySlCIEILK DDUJIEEIJED $373K ligfifidlllaFEEOD
6: 5 739331;}! \JSODIEfii Elfifi L $30

, Sn+Ag+Cu<§3+£§+il®
. Sn+Cu<§S+$fi>
, Sn+Zn+Bl(i§+fifid+EX?X)

31% 3
31%?dlly9035flfifilgl3iéfiwfidkbl \jélltleSOoAODC
EEE EtEEIififi< Tiébta