Yamaha htr 6080 dsp ax861
This is the 143 pages manual for yamaha htr 6080 dsp ax861.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.
Extracted text from yamaha htr 6080 dsp ax861 (Ocr-read)
Page 1
Av RECEIVER/AV AMPLIFIER
RX-V861/HTR-6080/DS P-AX861 SE/
DSP-AX861
SERVICE MANUAL
IMPORTANT NOTICE
This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.
It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA PfoduCIs, are already
known and understood by the users, and have therefore not been restmedr
WARNING:
Failure to follow appropriate service and safety procedures when servicing this product may result in personal
injury, destruction of expensive components, and failure ofthe product to perform as specified. For these reasons,
we advise all YAMAHA product owners that any service required should be performed by an authorized
YAMAHA Retailer or the appointed service representative.
IMPORTANT: The presentation or sale ofthis manual to any individual or firm does not constitute authorization, certification of
recognition of any applicable technical capabilities, or establish a principleragem relationship of any form.
The data provided is believed to be accurate and applicable to the unil(s) indicated on the cover. The research, engineering, and
service deparmients of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, ineviiable
and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist please
COIIlrICI Ihe disiribumf's Service Division.
WARNING:
Static discharges can destroy expensive components. Discharge any static electricity your body may have
accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss).
IMPORTANT: Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit.
I CONTENTS
To SERVICE PERSONNEL
FRONT PANELS .................
REAR PANELS ......................
REMOTE CONTROL PANELS.
SPECIFICATIONS/ $$Iil§
INTERNAL VIEW .......................................
DISASSEMBLY PROCEDURES I fiflfifllfi.
UPDATING FIRMWARE /
13
.14-19
77-A'7170Eifl7i ..................................... 20-27
SELF DIAGNOSIS FUNCTION (DIAG) /
Eaaaimee (57477") ..................................... 28-55
CONFIRMATION OF IDLING CURRENT OF AMP UNIT/
7>7127 IQTTFU/7%Bfifl)§§§€ ................. 56
:0v75x7:17M1t 1:777aimfiiifififfiffi bthh
This Service Manual uses recycled paper.
101043
© 2007 YAMAHA CORPORATION All nghls reserved.
This manual is copyrighted by VAMAHA and may not be copied or
redistributed either in print oreiecironicaiiy Without permission.
DISPLAY DATA
IC DATA .........
PIN CONNECTION DIAGRAMS.
BLOCK DIAGRAMS ..
PRINTED CIRCUIT BOARDS
SCHEMATIC DIAGRAMS ...... .. 97-107
REPLACEMENT PARTS LIST 109-135
REMOTE CONTROL ........ 136-139
ADVANCED SETUP / zilfiwaaiifigfi'sé. 140-142
SCENE CONTROL.. 143
YAMAHA
YAMAHA CORPORATION
P.O.Box 1. Hamamalsu, Japan
g 07.04
D
2
<
(XI
01
.a
\
E.
U
w:
3:
x2
0°C
20)
I
>
X
(XI
01
-
U)
m
Page 2
m
V)
_
{O
on
X
F
n.
(I)
D
\
c
w
o
9
C:
l-
I
\
,.
ID
no
>.
X
I
DSP-AX861
RX-V861lHTR-6080/DSP-AX861SE/DSP-AX861
I TO SERVICE PERSONNEL
1. Critical Components Information
Components having special characteristics are marked "t
and must be replaced with parts having specifications equal
to those originally installed.
2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.
0 Meter impedance should be equivalent to 1500 ohms shunted
by 0.1 stiF.
For U model
E9 CAUTION"
iAiV F251, F252:
TYPE 10A, 125V FUSE."
For C model
CAUTION
F251, F252:
A'I'I'ENTION
F251 , F252:
AC LEAKAGE
WALL EQUIPMENT TESTER OR
OUTLET UNDER TEST EQUIVALENT
@ID-
J;-
INSULATING
TABLE
0 Leakage current must not exceed 0.5mA.
0 Be sure to test for leakage with the AC plug in both polarities.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME
REPLACE WITH SAME TYPE 10A, 125V FUSE.
UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE10A, 125V.
WARNING: CHEMICAL CONTENT NOTICE!
The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and/or plastic (where
applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency (and
possibly other entities) to cause cancer and/or birth defects or other reproductive harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REA-
SON WHATSOEVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose
eyes to solder/flux vapor!
If you come in contact with solder or components located inside the enclosure of this product, wash your hands before
handling food.
About lead free solder / #fiéfi / $1" I: OL \ T
All of the P.C.B.s installed in this unit and solder joints are
soldered using the lead free solder.
Among some types of lead free solder currently available,
it is recommended to use one of the following types for the
repair work.
- Sn + Ag + Cu (tin + silver + copper)
- Sn + Cu (tin + copper)
- Sn + Zn + Bi (tin + Zinc + bismuth)
Caution:
As the melting point temperature of the lead free solder is
about 30"C to 40°C (50°F to 70°F) higher than that of the lead
solder, be sure to use a soldering iron suitable to each solder.
$$|C3§§iéfltb)éi&t®§tfificfilfl \jiltiljllckéfié
ERIK? u/ \J9E/ \ygfiljéfitmiiu
flit/til\)§ICI3L\<3D®T§§{EDEDi373 lléfEEélCQTEEOD
diiflfiiifiulkyéiODlEfifiEiEfiL/ifig
. Sn+Ag+Cu(§Ei+$E+fifi)
. Sn+Cu
. Sn+Zn+Bi(§%+fifia+EX7X)
535% 1
fittficl/ \JSUJEEFEEEHEfiUJSSADJ \79l:tl§\80~40€
EEE