Yamaha htr 5690
This is the 147 pages manual for yamaha htr 5690.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.
Extracted text from yamaha htr 5690 (Ocr-read)
Page 1
AV RECEIVER/Av AMPLIFIER
RX-V2400/RX-V2400RDS/DSP-AX2400
RX-VI400lRX-V1400RDS/HTR-5690/DSP-AX1400
SERVICE MANUAL
/
IMPORTANT NOTICE
This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.
It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already
known and understood by the users, and have therefore not been restated.
WARNING: Failure to follow appropriate service and safety procedures when servicing this product may result in personal
injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons,
we advise all YAMAHA product owners that any service ruluired should be performed by an authorized
YAMAHA Retailer or the appointed servroe representative.
IMPORTANT: The presentation or sale of this manual to any individual or firm does not constitute authorization, certification or
recognition ofany applicable technical capabilities, or establish a principleragent relationship of any form.
The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and
service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitable
and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please
contact the distributor's Service Division.
WARNING: Static discharges can destroy expensive components. Discharge any static electricity your body may have
accumulamd by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss).
IM PORTANT: Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit.
\
I CONTENTS
TO SERVICE PERSONNEL 2
FRONT PANELS.. ..... ..... ..... ..... ..... ..... 3~5
REAR PANELS ......
REMOTE CONTROL.
SPECIFICATIONS..
INTERNAL VIEW .......................................
DISASSEMBLY PROCEDURES / fiflfifllfi
UPDATING FIRMWARE/
77-A'717wgaiiya ..................................... 23~24
SELF DIAGNOSIS FUNCTION (DIAG)/
EEfizlfifiaE (sir/77) .
25~49
:mv-Ezvzambu. I:7-9!20i£k§§fllfib1tl!fe
This Sarviw Manual uses Iowalsd paper.
Copyright 2003 YAMAHA CORPORATIOND
This manual is copyrighted by YAMAHA and may not be copied or D
redistributed either in print orelectronically without permissionu
100867
AMP ADJUSTMENT] 7>7ifl3sfil¥ ..................... 50~51
DISPLAY DATA ..................................................... 52~53
Ic DATA .54~63
BLOCK DIAGRAM. . 64~65
PRINTED CIRCUIT BOARD 66~85
PIN CONNECTION DIAGRAM 86
SCHEMATIC DIAGRAM 87~97
PARTS LIST ................ 99~141
REMOTE CONTROL....... ..... ...... .. ...... .. ...... 142~147
Parts List for Carbon Resistors .............................. 14B
YAMAHA
YAMN-IA CORPORATION
P.O.Box 1, Hamamatsu, Japan
Page 2
c:
o
a
m
><
F
o.
w
E
U)
n
u:
o
o
a
m
>.
><
E
a
o
V
w
>.
><
o:
RX-VI400/RX-V1400RDSIHTR-5690/DSP-AX1400
RX-V2400IRX-V24OORDSIDS P-AX2400
RX-V1400IRX-V1400RDSIHTR-5690lDSP-AX1400
I TO SERVICE PERSONNEL
C.ritical Components Information
Components having special characteristics are marked [K
and must be replaced with parts having specifications equal
to those originally installed.
2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it Is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.
0 Meter impedance should be equivalent to 1500 ohm shunted
by015uF
AC LEAKAGE
WALL EQUIPMENT TESTER OR
OUTLET UNDER TEST EQUIVALENT
®:D-
;
INSULATING
TABLE
0 Leakage current must not exceed 0.5mA.
0 Be sure to test for leakage with the AC plug in both polarities.
CAUTION
F1, F2: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 10A,
125V FUSE.
CAUTION
F1, F2: REPLACE WITH SAME TYPE 10A, 125V FUSEt
ATTENTION
F1, F2: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 10A, 125V.
WARNING: CHEMICAL CONTENT NOTICE!
The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and/or plastic (where
applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency (and
possibly other entities) to cause cancer and/or birth defects or other reproductive harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REA-
SON WHATSOEVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose
eyes to solder/flux vapor!
If you come in contact with solder or components located inside the enclosure of this product, wash your hands before
handling food.
About lead-free solder / fifil \ > 51 I: 3
The Ioil side of all P.C.B.:s used for this product are
soldered with lead-free soldering material which is an alloy
of Sn+Ag+Cu (tin + silver + copper).
However, the surface mount devices on the component
side of the DSP P.C.B., FUNCTION P.C.B. and
CONVERSION P.C.B. are soldered with the lead solder.
Among some types of lead-free solder currently available,
it is recommended to use one of the following types for the
repair work.
- Sn + Ag + Cu (tin + silver + copper)
- Sn + Cu (tin + copper)
- Sn + Zn + Bi (tin + zinc + bismuth)
Caution:
1. As the melting point temperature of the lead-free solder
is about 30°C to 40°C (50°F to 70°F) higher than that of
the lead solder, be sure to use a soldering iron suitable
to each solder.
2. If lead solder must be used, be sure to remove lead-
free solder from each terminal section of the parts to be
replaced and from the area around it completely before
soldering, or make sure that the lead-free solder and
lead solder melt together fully.
LT
Z®§&EfifiehfwéfNT®§W®H>§fi®n>
fifttttICIi, Sn+Ag+Cu(fiamflflmsecabwfien>
Yamahas-90
ram/x DSP P.C.B.\ FUNCTION P.C.B.?sétl)
CONVERSION P.C.Bsmfiofififlesmmxworm
Iztaizallilwsffifififieinfinite
flatten > so: In) < o image's I) s Th); fewer: Ii
T230); 5 Mess/wsmiemsms L $10
- Sn+Ag+Cu(§-§+3E+§l§)
- Sn+Cu(§E+$fi)
- Sn+Zn+Bi(§5+§$a+ I52 7 X)
as:
®fists/xwjmataiagiiteetmskUlwaizflmao
~4o°Ct§EFei
@iAU/waerahssets tweet: asaumfi
mmsraeesrememmeasnm a TNTEY
Ulte< 75x 356bl1fifld/\>7t£all)/\/$I'fi"+$}ll
filtfflfifiétikbctiiinzfifiltL(