Yamaha htr 2064
This is the 96 pages manual for yamaha htr 2064.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.
Extracted text from yamaha htr 2064 (Ocr-read)
Page 1
HOME THEATER PACKAGE YHT-196
RECEIVER / SPEAKERS
HTR-2064 /
NS-BZO/NS-CZO/NS-SWPZO
The YHT-196 consists Of the HTR-2064, NS-BZO, NS-C2O and NS-SWP20.
Note:
- When the following parts are replaced, the destination MUST be written to the back-up IC (EEPROM: I0222 on
DIGITAL ROB.) to have proper operation. (For details, refer to No.22 SOFT SWITCH menu of the self-diagnostic
function.)
DIGITAL P.C.B.
EEPROM: |0222 on DIGITAL PCB.
- When the power amplifier IC ([0 1 or IC 2 on MAIN P.C.B.) requires to be replaced, be sure to refer to POWER
AMPLIFIER IC REPLACEMENT before its replacement.
IMPORTANT NOTICE
Tlus manual has been proyrded for rhe use ofaruhorrzed YAMAHA Relarlers and rherr sen rce personnel,
h has been assumed rhar basrc semce procedures Inherent re the industry, and more speerhcally YAMAHA Products. are already known
and understood by rhe users, and llme rherefore not been restated.
WARNING:
Farlure ro follow appropriate semee and safety procedures when seryrcrng this product may resulr ln personal rnprry,
desrnrehon of expensrve components, and farlure of the producr to perform as specrfied. For these reasons, we advrse
all YAMAHA product owners tllal any seruce reqrured should be performed by an anrhorrzed YAMAHA Relaller or
the appornred service represemarrve.
IMPORTANT: The presenrarlon or sale of rhls manual ro any mdrvldual or firm does not consume authorizanon. cemficanon or
recognmon ofany appheahle rechnrcal capabrlmes. or esrabhsh a principleragem relanonshrp ofany form.
The dara proyrded rs beheyed to be accurate and apphcable to rhe uml(s) rndreared on the cover, The research. engineering. and semce
deparrmenrs of YAMAHA are conrrnually slrlvmg ro Improve YAMAHA producrs, Modrfrcanons ares rherefore, lnevilable and
speerficarrons are subject to change wrrhour nouce or obllgatlon to retrofit. Should any drserepaney appear ro exrsr, please conracl lhe
distributor's Service Division,
WARNING: Slauc dlseharges can desrmy expensrve components. Dlscharge any static eleclrrclry your body may have
accunrulared by groundlng yourself to Ille ground buss rn lhe unu (heavy gauge hlaek wrres connect to rhrs buss).
IMPORTANT: Tum rhe unlt OFF during drsassemhly and pan replacemenr, Reeheek all work before you apply power 10 the unit.
I CONTENTS
2
.
o
M
Q
2
.
(n
E
'u
N
O
IOZH'SNIVBOZ'HLH
SELF-DIAGNOSTIC FUNCTION
TO SERVICE PERSONNEL 2
SYSTEM COMPOSITION .3
FRONT PANELS ............ -4
REAR PANELS .....................
REMOTE CONTROL PANEL
SPECIFICATIONS .
INTERNAL VIEW ..
SERVICE PRECAUTIONS .
POWERAMPLIFIER IC REPLACEMENT
DISASSEMBLY PROCEDURES .
UPDATING FIRMWARE ..............
' :mv- EXVZJTJML137-7igfimfiirlfifilfifi i/TwiTr
ans Servrce Manual uses recycled paper.
DISPLAY DATA
IC DATA ...........
PIN CONNECTION DIAGRAMS .
BLOCK DIAGRAM ................
PRINTED CIRCUIT BOARDS
SCHEMATIC DIAGRAMS
REPLACEMENT PARTS LIST .
REMOTE CONTROL
ADVANCED SETUP .
YAMAHA
YAMAHA CORPORATION
P.O.Bo 1, Hamamatsu, apan
l 1.12
Copyngnr © 2011 YAMAHA CORPORATION All ngnrs reserved.
This manual is copyrighted by YAMAHA and may nor be Copied or
redistributed elther m pnnr or elecrrenrcally without permissmn.
Page 2
HTR-2064/NS-BZO/NS-CZOINS-SWPZO
I TO SERVICE PERSONNEL AC LEAKAGE
1. Critical Components Intormation WALL EQUIPMENT TESTER OR
Components having special characteristics are marked A and OUTLET UNDER TEST EQUIVALENT
must be replaced with parts having specifications equal to those
originally installed. ® :ID
2. Leakage Current Measurement (For 120V Models Only) J_-
When service has been completed, it is imperative to verify INSULATING _
that all exposed conductive surfaces are properly insulated TABLE
from supply circuits.
- Meter impedance should be equivalent to 1500 ohms shunted 0 Leakage current must not exceed 0.5mA.
by 0-15 IJF- 0 Be sure to test for leakage with the AC plug in both polarities.
For U model
133 CAUTION
F1501: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 6A,
125V FUSE."
For C model
CAUTION
F1501: REPLACE WITH SAME TYPE 6A, 125V FUSE.
ATTENTION
F1501: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 6A, 125V.
WARNING: CHEMICAL CONTENT NOTICE!
This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive
harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REASON
WHATSOEVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or
expose eyes to solder/flux vapor!
It you come in contact with solder or components located inside the enclosure of this product, wash your hands before
handling food.
HTR-2064INS-520/
O
N
D.
E
q:
a:
E
O
N
o
w
2
About lead free solder
All of the P.C.B.s installed in this unit and solder joints are soldered using the lead free solder.
Among some types of lead free solder currently available, it is recommended to use one of the following types for the
repair work.
0 Sn + Ag + Cu (tin + silver + copper)
0 Sn + Cu (tin + copper)
0 Sn + Zn + Bi (tin + Zinc + bismuth)
Caution:
As the melting point temperature of the lead free solder is about 30°C to 40°C (50°F to 70°F) higher than that of the lead
solder, be sure to use a soldering iron suitable to each solder.