Av RECEIVER/Av AMPLIFIER
RX-V863/HTR-61 80/
DSP-AX863SE/DSP-AX863
SERVICE MANUAL
/
contact the distributor's Service Division.
\
I CONTENTS
TO SERVICE PERSONNEL .......................................... 2
FRONT PANELS ........................................................ 3-5
REAR PANELS .................... . 6-10
REMOTE CONTROL PANELS .................................... 11
SPECIFICATIONS/$%Iߤ ................................ 12-15
INTERNAL VIEW ............... 15
DISASSEMBLY PROCEDURES Ififififlfi .......... 16-21
UPDATING FIRMWARE /
77-A017GDE55AJ; .................................. 22-36
SELF DIAGNOSIS FUNCTION (DIAG) /
a 3:91am: (5% 77) .................................. 37-63
CONFIRMATION OF IDLING CURRENT OF AMP UNIT/
7>7°1:»y t~ 037+ I< U >7aaemaaa ............... 64
:o#- EX7=171I1I1\ I: v-aatmfiifiim bro: 1'.
This Service Manual uses recycled paper.
101088
IMPORTANT NOTICE
This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.
It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already
known and understood by the users, and have therefore not been restated.
WARNING: Failure to follow appropriate service and safety procedures when servicing this product may result in personal
injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons,
we advise all YAMAHA product owners that any service required should be performed by an authorized
YAMAHA Retailer or the appointed service representative.
IMPORTANT: The presentation or sale of this manual to any individual or firm does not constitute authorization, certification or
recognition of any applicable technical capabilities, or establish a principle-agent relationship of any form.
The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and
service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitable
and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please
WARNING: Static discharges can destroy expensive components. Discharge any static electricity your body may have
accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss).
IMPORTANT: Turn the unit OFF during disassembly and part replacement. Recheek all work before you apply power to the unit.
@2008 mm All fights reserved
ThIs manual Is copyrIghied by YAMAHA and may not be cooled Dr
redIstrIbuied eIther In prInt or electmmcallywnhoui permISSIDn
\
/
DISPLAY DATA ........................................................... 65
IC DATA ................................................................. 66-82
PIN CONNECTION DIAGRAMS .. 83-86
BLOCK DIAGRAMS .............................................. 87-91
PRINTED CIRCUIT BOARDS .............................. 92-105
SCHEMATIC DIAGRAMS .................................. 107-117
REPLACEMENT PARTS LIST .......................... 119-147
REMOTE CONTROL .......................................... 148-1 51
ADVANCED SETUP Ixeoaaeéaeaa 152-154
Using BluetOOth components]
BIuetoothifia-Eéfii'st é ........................................ 155
.YAMAHA
YAMAHA CDRFORAI'ION
PO Box 1, Hamamatsu, Japan
I 08.03
D
(0
"Fa:
32:
$00
«>3
8%
83.0
"P2
>00
0
$5..
0')
(A)
Page 2
\
O
m
,_
P
a:
I-
I
\
(a
(D
N
>.
X
Ct:
DSP-AX863SE/DSP-AX863
RX-V863/HTR-6180lDSP-AX863SE/DSP-AX863
I TO SERVICE PERSONNEL
1. Critical Components Information
Components having special characteristics are marked x!\
and must be replaced with parts having specifications equal
to those originally installed.
2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.
0 Meter impedance should be equivalent to 1500 ohms shunted
by 0.15uF.
AC LEAKAGE
WALL EQUIPMENT TESTER OR
OUTLET UNDER TEST EQUIVALENT
®=D-
J.-
INSULATING
TABLE
0 Leakage current must not exceed 0.5mA.
0 Be sure to test for leakage with the AC plug in both polarities.
For U model
IEEI CAUTION
47" F2501, F2502: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME
TYPE 10A, 125V FUSE."
For C model
CAUTION
F2501, F2502: REPLACE WITH SAME TYPE 10A, 125V FUSE.
ATTENTION
F2501, F2502: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 10A, 125V.
WARNING: CHEMICAL CONTENT NOTICE!
This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive
harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY
REASON WHAT SO EVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose
eyes to solder/flux vapor!
It you come in contact with solder or components located inside the enclosure of this product, wash your hands before
handling food.
About lead free solder / 1H9! \ / 3! I: 3 I. \ T
All of the P.C.B.s installed in this unit and solderjoints are
soldered using the lead free solder.
Among some types of lead free solder currently available,
it is recommended to use one of the following types for the
repair work.
~ Sn + Ag + Cu (tin + silver + copper)
~ Sn + Cu (tin + copper)
- Sn + Zn + Bi (tin + zinc + bismuth)
Caution:
As the melting point temperature of the lead free solder is
about 30°C to 40°C (50°F to 70°F) higher than that of the lead
solder, be sure to use a soldering iron suitable to each solder.
maictsaantueastwataasgo; tyfildljlcotétfié
élfilatfifi/u} \ygT) \yyidljéitCMigx
fifiul \JélllatLK DDUDEiiE-bafi D $375K I|EEEB§ICI$TEE®
a: 5 Ufificil \JSUJIfifiiEIEiE bigo
- Sn+Ag+Cu(§5+§E+filfil)
- Sn+Cu(§%+$fi)
~ Sn+Zn+Bi(§%+fifil:l+l:7\77\)
51% 3
fittfifi/ \Ufiwfififiifiglififiwfifilm \VfilCJZISN30~4O°C
IEEE< UD-CLIBEg'ODT %fl%l1®/\J§l:éofc)\7§
EKECt§fi3< fiat,