Sony str d 360 z service manual
This is the 18 pages manual for sony str d 360 z service manual.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.
Extracted text from sony str d 360 z service manual (Ocr-read)
Page 1
Ñ 2 Ñ TABLE OF CONTENTS Specifications ááááááááááááááááááááááááááááááááááááááááááááááááááá\ áááááááááááááááááááááááááááá 1 1. GENERAL Location and Function of controls áááááááááááááááááááááááááááááááááááááááááááááááá 4 2. EXPLANATION OF IC TERMINALSááááááááááááááááááá 5 3. DIAGRAMS 3-1. Circuit Boards Location ááááááááááááááááááááááááááááááááááááááááááááááááááá\ áá 7 3-2. Printed Wiring Boards (MAIN SECTION) áááááááááááááááááááááááá 9 3-3. Schematic Diagram (MAIN SECTION) áááááááááááááááááááááááááá 13 3-4. Schematic Diagram (DISPLAY SECTION) áááááááááááááááááááá 18 3-5. Printed Wiring Boards (DISPLAY SECTION) áááááááááááááááá 21 4. EXPLODED VIEWS 4-1. Front Panel Section ááááááááááááááááááááááááááááááááááááááááááááááááááá\ ááááááá 25 4-2. Chassis Section ááááááááááááááááááááááááááááááááááááááááááááááááááá\ áááááááááááááá 27 5. ELECTRICAL PARTS LISTáááááááááááááááááááááááááááááááá 29
Page 2
Pin No.123456789101112131415161718192021222324252627282930313233343536373839 40 I/OOOOOOOOÑIIIOOÑÑIIIIÑOOOÑIIIIÑÑÑÑÑÑÑOOOO O Description Fluorescent indicator tube drive. Power supply (+5V).System clock.System data.PLL data input from TU001.Chip enable output.Chip enable output.Not used.Not used. (Open)Protector detect input.System reset terminal.Auto stop detect input.Stereo detect input.Ground.Speaker relay drive.Surround Relay.Power relay drive.Not used.A/D signal input terminal.A/D3 key input terminal.A/D2 key input terminal.A/D1 key input terminal.Power supply (+5V).Reference voltage (+5V).Ground.Not used (Open).Ground.System clock (4.19MHz).System clock (4.19MHz).Mute drive output for mPD2581V (IC701).Plologic LED.CINEMA STUDIO LED.HALL LED. Tuner mute drive output. Pin NameDIG7DIG6DIG5DIG4DIG3DIG2DIG1+5VS. CLKS. DATAPLL. DATAS. CE (LC7288)S. CE (LV100)REARRYBRIDGE CABLEPROTECTRESETAUTO-STOPSTEREO-INAVssSP-RYSURR-RYPOWER-RYNot usedSIGNALA/D3A/D2A/D1AVDDAV. R E FGNDNCVssX1X2IC. MUTEPROLOGICCSTUDIOHALL T. MUTE SECTION 2 EXPLANATION OF IC TERMINALS Pin No.414243444546474849505152535455565758596061626364656667686970717273747576777879 80 I/OOOOIIIIÑIIÑÑÑOÑIIIIIÑOOOOOOOOOÑOOOOOOOO O Description Volume up.Volume down.Standby LED drive.System power ON/OFF.RDS data input. (AEP, SP. MY, CH model)RDS clock input. (AEP, SP, MY, CH model)Stop signal input from NJM2103D (IC950).Ground.Sircs signal input.Power switch input terminal.Not used,Power supply (+5V).Bass boost LED drive.Line mute drive.Not used.Input for model select.Key in 4.Key in 3.Key in 2.Key in 1.Not used.Key out 1Key out 2Key out 3Key out 4 Connect to Ð24V. Fluorescent indicator tube drive. Pin NameVOLUME UPVOLUME DOWNSTANDBYSYS. POWERRDS. DATA. INRDS. CLK. INSTOPVssSIRCSPOWER SW5.1ch LED+5VBASS BOOSTFUNC. MUTESL MUTEVERSIONK14K13K12K11SR MUTES15S14S13S12S11S10S9S8S7VLOADS6S5S4S3S2S1DIG10DIG9 DIG8 SECTION 3 DIAGRAMS ü ï ï ï ï ï ï ï ý ï ï ï ï ï ï ï þ Fluorescent indicator tube drive. 3-1. CIRCUIT BOARDS LOCATION Ñ 3 ÑÑ 4 ÑÑ 5 ÑÑ 6 ÑÑ 7 Ñ ¥ IC201 mPD78044FGF-041-3B9 After correcting the original service problem, perform the following safety checks before releasing the set to the customer: Check the antenna terminals, metal trim, ÒmetallizedÓ knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below. LEAKAGE The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microampers). Leakage current can be measured by any one of three methods. 1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturersÕ instructions to use these instruments. 2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job.3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The ÒlimitÓ indication is 0.75 V, so analog meters must have an accurate low-voltage scale. The Simpson 250 and Sanwa SH-63Trd are examples of a passive VOM that is suitable. Nearly all battery operated digital multimeters that have a 2V AC range are suitable. (See Fig. A) SAFETY CHECK-OUT To Exposed Metal Parts on Set 0.15 µF 1.5k ½ AC voltmeter (0.75V) Earth Ground Fig. A. Using an AC voltmeter to check AC leakage. SAFETY-RELATED COMPONENT WARNING!! COMPONENTS IDENTIFIED BY MARK ! OR DOTTED LINE WITH MARK ! ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUB-LISHED BY SONY. ATTENTION AU COMPOSANT AYANT RAPPORT Ë LA SƒCURITƒ! LES COMPOSANTS IDENTIFƒS PAR UNE MARQUE ! SUR LES DIAGRAMMES SCHƒMATIQUES ET LA LISTE DES PIéCES SONT CRITIQUES POUR LA SƒCURITƒ DE FONCTIONNEMENT. NE REMPLACER CES COMPOSANTS QUE PAR DES PIéSES SONY DONT LES NUMƒROS SONT DONNƒS DANS CE MANUEL OU DANS LES SUPPƒMENTS PUBLIƒS PAR SONY. SECTION 1 GENERAL LOCATION AND FUNCTION OF CONTROLS SP SW (A)PRIMARYSECONDARY SELECTOR STBY VIDEO VOLUME VR TONE KEY DISPLAY SP SW (B) SW MAIN D360Z DE315 DE415 US, Canadian model : AC 120V 60Hz Australian model : AC 240V ~50/60Hz E model : AC 120, 220, 240V selectable ~50/60Hz Singapore, Malaysia, Chinese model : AC 230V ~50/60Hz MODEL IDENTIFICATION MODEL NO. FM STEREO/FM-AM RECEIVER STR -