Page 1
HCD-CP101
SECTION 4
TEST MODE
[COLD RESET]
. The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning
the set to the customer.
Procedure:
1. Turn ON the power.
2. Press three buttons of E (TAPE), E (CD), and siA
multaneously.
3. The set is reset.
[LIQUID CRYSTAL DISPLAY ALL LIT CHECK MODE]
Procedure:
1. Set to standby state.
2. Press three buttons of E (TAPE), E (CD), and
simultaneously.
3. Liquid crystal display are all turned on.
4. To exit from this mode, press the button to turn the power
OFF.
[TAPE DECK AGING MODE]
This mode can be used for operation check of tape deck section.
Procedure:
1. Set a tape in the tape deck.
2. Set to standby state.
3. Press three buttons of E (TAPE), E (CD), and
simultaneously.
4. The aging is executed in bellow sequence.
5. To exit from the aging mode, press the button to turn the
power OFF.
Aging mode sequence:
Start
Sh ff
FWD Play Ut 0
1 minute
REC pause for 3 seconds
Ft E C> Shut off
3 minutes
Fast forward
A
M
REV Play 57! a
1 minute
REC pause for 3 seconds
HM
Sh ff
REV REC ut 0
3 minutes
Rewind
H
12
[CD AGING MODE]
This mode can be used for operation check of CD section.
Procedure:
1. Load a CD disc.
2. Set to standby state.
3. Press three buttons of E (TAPE), E (CD), and
simultaneously.
4. The aging is executed in bellow sequence
5. To exit from the aging mode, press the button to turn the
power OFF.
Aging mode sequence:
Start
Open the disc [ray
Close the disc tray
Play the last [rack
[CHANGE-OVER MD/VIDEO]
Procedure:
I. Set to standby state.
2. Press the E (CD) and the buttons simul-
taneously.
The function changes over to MD or VIDEO by turns.
[CHANGE-OVER THE AM TUNING INTERVAL]
(EXCEPT AEP and UK models)
' The AM tuning interval can be changed over 9 kHz or 10 kHz.
Procedure:
1. Press the button to turn the power ON.
2. Select the function TUNER, and press the button
to select the BAND AM".
3. Press the button to turn the power OFF.
4. Change over to 9 kHz:
Press the and the E (CD) buttons simultaneously.
Change over to 10 kHz:
Press the and the E (CD) buttons simultaneously.