Pioneer dv 668 avs service manual
This is the 170 pages manual for pioneer dv 668 avs service manual.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.
Extracted text from pioneer dv 668 avs service manual (Ocr-read)
Page 1
Pioneer sound. vision. soul
Service
Manual
ORDER NO.
RRV281 6
DvrseAVi
DVD PLAYER
I
5 I
I
DV- 8 6 8 AV I - S
DV- 6 6 8 AV- S
THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S).
Serial No.
Model Type Power Requirement Region No. Confirm 3rd & 4th
alphabetical letters.
DV-59AVi KUXJ/CA AC120V 1 &&MP######$$
DV-868AVi-S WYXJ A0220-240V 2 &&MP######$$
DV-SGSAV-S WYXJ A0220-240V 2 &&MP######$$
09
For details, refer to "Important symbols for good services".
PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan
PIONEER ELECTRONICS (USA) INC. P.O. BOX 1760, Long Beach, CA 90801-1760, U.S.A.
PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium
PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01, Singapore 159936
©PIONEER CORPORATION 2003 T-ZZE DEC 2003 printed in Japan
Page 2
1 - 2 - 3 - 4
SAFETY INFORMATION
I]
This service manual is intended for qualified service technicians; it is not meant for the casual
do-it-yourselfer. Qualified technicians have the necessary test equipment and tools, and have been
trained to properly and safely repair complex products such as those covered by this manual.
Improperly performed repairs can adversely affect the safety and reliability of the product and may
void the warranty. If you are not qualified to perform the repair of this product properly and safely, you
should not risk trying to do so and refer the repair to a qualified service technician.
WARNING
This product contains lead in solder and certain electrical parts contain chemicals which are known to the state of California to
cause cancer, birth defects or other reproductive harm.
Health & Safety Code Section 25249.6 - Proposition 65
NOTICE
(FOR CANADIAN MODEL ONLY)
Fuse symbols EH (fast operating fuse) and/or a (slow operating fuse) on PCB indicate that replacement
parts must be of identical designation.
REMARQUE
(POUR MODELE CANADIEN SEULEMENT)
Les symboles de fusible EEI- (fusible de type rapide) et/ou a (fusible de type lent) surCCl indiquent que
les pieces de remplacement doivent avoir la meme designation.
-(FOR USA MODEL ONLY)
1. SAFETY PRECAUTIONS ANY MEASUREMENTS NOT WITHIN THE
The following check should be performed for the LIMITS OUTL|NED ABOVE ARE |ND|CAT|VE
conhtinued protection of the customer and service OF A POTENTIAL SHOCK HAZARD AND
EEAIEIAEE CURRENT CHECK MUST BE CORRECTED BEFORE RETURN-
Measure leakage current to a known earth ground ING THE APPLIANCE TO THE CUSTOMER-
(water pipe, conduit, etc.) by connecting a leakage
current tester such as Simpson Model 229-2 or 2_ PRODUCT SAFETY NOTICE
equivalent between the earth ground and all exposed
, , . Many electrical and mechanical parts in the appliance
metal parts of the appliance (input/output terminals,
have special safety related characteristics. These are
screwheeds. metal overlays, control shaft, etc-)- Plug often not evident from visual inspection nor the
the AC line cord of the appliance directly into a 120V protection afforded by them necessarily can be obtained
AC 60 Hz outlet and turn the AC power switch on. Any by using replacement components rated for voltage,
current measured must not exceed 0.5 mA. wattage, etc. Replacement parts which have these
special safety characteristics are identified in this
Service Manual.
Electrical components having such features are
:{ifgbsohvgu'd identified by marking with a A on the schematics and
Leakage 0,5 m on the parts list in this Service Manual.
Device 5:55," The use of a substitute replacement component which
under
I does not have the same safety characteristics as the
es
PIONEER recommended replacement one, shown in the
parts list in this Service Manual, may create shock, fire,
or other hazards.
Product Safety is continuously under review and new
instructions are issued fromtime to time. For the latest
information, always consult the current PIONEER
Service Manual. A subscription to, or additional copies
rblsginworszgame, of, PIONEER Service Manual may be obtained at a
plug as required) 7 ground nominal charge from PIONEER.
AC Leakage Test
Test all
exposed metal
surfaces
Also test with
Qit
DV-59AVi