Philips 22 ah 603 service manual 1

This is the 13 pages manual for philips 22 ah 603 service manual 1.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.

Page: 1 / 13
philips 22 ah 603 service manual 1

Extracted text from philips 22 ah 603 service manual 1 (Ocr-read)


Page 2

Before proceeding to trimming, short-circuit
point 14 of IC 6111 by connecting it to the mass.

Switch off the AFC (automatic frequency control)
Interrupt solder bridge

Adjust the R.F. generator in such a way that
a symmetrical response curve is obtained on
the screen (= f0 5110).

The input signal shall be as low as possible.
Adjust for maximum linearity of the S-curve.
Close solder bridge

Adjust for zero-axis crossing (red LED shall
burn glaringly).

Mark at scale.
Meter deflection > 8 divisions.
Eliminate short-circuit at point 14 of IC 6111.

Adjustment output amplifier

Direct current adjustment - Left (Right).

With the aid of R3527 (3523) adjust the quiescent
current through the output transistors to 50 mA 1 5 % .
To be measured with a non-earthed mV-meter connected
across the resistors 3505, 3507 (3506, 3508).

The deflection shall then be 32 mV : 5 %.

Inspection DC protection

- Connect a resistor of 180 k0 between the negative
pole of C2411 and point +1 of the power supply.
The relay shall then be released.

- Connect a resistor of 150 kfl between the negative
pole of 02414 and point -1 of the power supply.
The relay shall then be released.

Eli

Elfll lElElEllEl

@

Véér het trimmen punt 14 IC 6111 kortsluiten
met massa.

AFC uitschakelen.
Soldeer brug W open

RF generator 10 instellen dat de doorlaatkromme
symmetrisch in beeld komt (= fo 5110).

lngangssignaal zo laag mogelijk houden.
Afregelen op max. lineariteit van de S-kromme.
Sluit brug

Afregelen op D-doorgang (Rode LED moet fel
branden).

Merkpunt op schaal.
Meteruitslag > 8 schaaldelen.
Kortsluiting punt 14 IC 6111 opheffen.

Align-mun! <:> , <> ¥ ,8, Q Alignment <> @ Cr:
Raging. SK... 2233; 305' l-"j Malice SK... (:)-> #1 1"") ., .
452 kHz _ 5111 ® (9 FM-HF FM 109 MHz Max. 5108

AM-IF MW E] 468 kHz Min. cap. 5121 Max_ + mm. M 75 kHz I
AM-Fl 470 kHz _ El
5120 1_fo 5115) 1mV
(=10 5115)
2106 0 +
1+ 1 kHz)
f <9 @151 Max.
0 5115 5111
86.8 MHz Min. 3258
5120 Q) Ar 75 kHz
5121 Min. + symm. 1mV + ®
AM-osc LW 147 kHz <2> or <9 505 Max.
(+1 kHz) ® Max. cap 5123
Max.
95.5 MHz @ 3257
MW 512 kHz At 75 kHz
(+1 kHz) 5122 1mV E] '3
1635 kHz Min ca 2197 STEREO FM 1"? 5114 ® or
(+1kHz) ' " DECODER 19 kHziZ Hz @ 10nF Min
100 mV 15 16 -
AM-RF MW 600 kHz ® Q 511 ® or <3) 1ce111
8
1+ 1 kHz) MM 100MHz
+ pil. tone 3179
LW 155 kHZ + R Mod ©
1+ 1 kHz) 5" ' ' Min.
MW 1500 kHz Stereo Decoder - Décodeur Stéréo - Decodificatore stereo - Stereodekoder
1+ 1 kHz) 236
1015 FM 95.5 MHz 3149 1015
Min. cap. 5107 5112 <1) + <5) 95-5
FM-IF FM [2| 5109 108 MH 3 5 0
5113 Max.+symm. z 1 1 1 5
t 10.7 MHz 108
Af 250 kHz
15° 2 5107 1016 PU 3217 1016
5109 0
MW 600 kHz
43> E] 10 mV ® 1016
©+ 6> El '
t 10.7 MHz 5113
El El 43> + @
< 20 mV _ 3 Repeat - Herhalen - Répéter - Wiederholen - Repetera - Ricomminciare - Gentage - Gjentagelse - Toista

Afrogelen cindverstcrker

Gelijkstroominstelling - L(R).

De ruststroom door de eindtransistoren moet ingesteld
worden met R3527 (3523) op 50 mA 1 5 % te meten met
een niet geaarde mV-meter aangesloten over de weer-
standen 3505, 3507 (3506, 3508).

De uitslag moet dan 32 mV 1 5 % Zijn.

Controls DC beveiliging

- Sluit een weerstand van 180 kfl aan tussen de - (min
pool) van C2411 en de +1 voeding.
Het relais moet dan afvallen.

- Sluit een weerstand van 150 k9 aan tussen de - van
(22412 en de 71 voeding.
Het relais moet dan afvallen.

C567 195