Phase Linear 8000 Series Service Manual
This is the 71 pages manual for Phase Linear 8000 Series Service Manual.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.
Extracted text from Phase Linear 8000 Series Service Manual (Ocr-read)
Page 1
MODEL 8000 SERIES TWO
LINEAR MOTOR TURNTABLE
Page 2
8000 SERIES TWO
LINEAR MOTOR ARM STEREO TURNTABLE
SERVICE MANUAL
CONTENTS:
P- p.
1-0. SPECIFICATIONS. . . . . . . . 3 7-0. ADJUSTMENTS . . . . . .28
_ 7.1 D.D.Motor Operating
2 0. PANEL FACILITIES. . . . . . . Point Adjustment. .29
3-0' DlgAisgzggg: 7.2 Auto Lead-In Timing
' ' ' ' ' ' ° ' ' Adjustment. . . . . .29
3.2 Direct Drive Motor. . . 9 7.3 End Sensor Sensi-
3.3 Tonearm . . . . . . . . 9 tivity Adjustment . .29
3.4 CdS Detector & Lamp .10 7.4 End Timer Adjustment.30
4-0. PARTS LOCATIONS . . . . . . .11 5 Tracking Sensor Zero
5-0. BLOCK DIAGRAMS/OPERATIONS . .13 Pomt ' ' ' ' ' '30
5.1 Tonearm Control Stage .15 7.6 Tracking Sensor Gain
5.2 End Detector Stage. . .15 Adjustment. ' ' ' ' '31
7.7 Lead-In and Return
5.3 Arm EV Control Stage. .15 Speed Adjustment. . 31
5.4 Size Selector Stage .15 8-0. TIMING CHART
5.5 Repeat Control Stage. .16 9_0. TROUBLESHOOTING:
5.6 Lowering Position 9.1 Circuit Block . . . .35
Detector, Plunger .
Control Stage, and . 9.2 Mechanism Block . . .44
Descent Signal 10-0.EXPLODED VIEWS. . . . . .51
Generator . . . . . .16 10.1 Exterior. . . . . . .53
5.7 Display Stage and 10.2 Bottom (Base)Plate. .56
Plunger Driver. ' '16 10.3 Tonearm Assembly. . .59
'8 Manual Drive Stage. ' '16 10.4 EV Mechanism. . . . .61
9 Tracking Sensor Stage
and Tonearm Driver ll-O. PACKING. . . . . . .62
Stage . . . . . . . .16 12-0. PRINTED CIRCUIT BOARD
510 D.D.Motor Control ASSEMBLIES . . . . . . . .63
Stage and D.D.Motor
Stop Control. . . . . .16
6-0. CIRCUIT DESCRIPTIONS. . . . .18
6.1 Full Auto Logic . . . .18
6.2 Tonearm Drive . . . . .25
* * * k * 7t * *
THIS MANUAL IS INTENDED FOR USE ONLY BY QUALIFIED TECHNICAL SERVICE
PERSONNEL. HAZARDOUS VOLTAGES MAY BE ENCOUNTERED IN THE TEST AND
SERVICING OF THE SOOOII. USE EXTREME CAUTION; READ ALL INSTRUCTIONS.
2
Page 17
rest. As long as the tonearm remains off the arm rest, the
motor will continue to rotate. The phono motor control stage
employs three specially designed IC's: PAZOOS, PA2004, and
PDlOO3. These control stages also include the speed selector,
speed indicator, and quartz lock indicator circuits.
End detector
Lowering position
detector
Fig. 5-2
17
Page 41
9.1.8
l
Is the repeat FF (IC12)
inverted every time the _
repeat switch is pressed ?
lYES
Are pins (11), (12) and
(13) of 109 switched from
H to L level (separately)
when the toneaxm passes
the corresponding record
size position when the
repeat switch is on?
Designated size
30cm -> pin (12)
Designated size
25cm -> pin (13)
Designated size
17cm -> pin (11)
lves
Is TPB switched to H
level during the above H Ni> Defective 1013
to L level switching?
NO Defective sensor circuit
board
. lves
Defective IC7 or defective
plunger
9.1.9
Tonearm fails to stop at
designated lowering posi-
tion
l
Are pins (11), (12) and
(13) of 1C9 switched from . . .
H to L level when the N0 stiestive sensor Circuit
toneaxm passes the desig-
nated lowering positions ?
lves
ls TP3 switched to H level
during the above H to L & Defective [013
level switching ?
yves
Defective 107 or defective
plunger
39