Octave voyetra 8 sysex implementation
This is the 7 pages manual for octave voyetra 8 sysex implementation.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.
Extracted text from octave voyetra 8 sysex implementation (Ocr-read)
Page 1
NOTES: 1. Bit 6 of the third Byte 1n the data stream is used as
NEH STEP
3 "Controller Flag". This flag is always zero on data
transmitted by the V8. The flag should be set on data
sent to the VB by a computer controller. This avoid:
conflicts when more than one VB.
"HX" refers te'the MIDI Niscellanenus panel function.
Sent by VB if NEW STEP is called from front panel and MX is on.
1111DBO¢
Bliiiiii
flpcccccc
Dsssssss
lillilla
Status byte
ID Number t i = 3; Octave-plateau
p = Controller flag I B for transmit data.
c = Command number x B.
s = Step number 3 0 - 99.
End of System Exclusive.
BULK DATA FOR 1 PROGRAM
Sent by VB when SYS.EX.command b is received and MX is an.
111xaaaa
mitiiiii
apcccccc
fimmmmmmm
aPPPPPPP
Enamdddd
11111110
Status byte
ID Number I 1 a 3; Octave-plateau
p a: Centreller flag a la fer transmit data.
c = Command number I 1.
Machine 1D I m = a for V8.
Program number : p = 9 ~ 99.
Data x sent as 45 bytes in 96 nibbles;
low nibble first.
End of System Exclusive.
BULK DATA FOR 1 STEP
Sent by VB when SYS.EX.cammand 7 is received and MX is an.
llllamma
Biiliili
chccccc
Dmmmmmmm
Dsssssss
@Qmmdddd
11111110
Status byte .
ID Number : 1 = 3; Octave-plateau
p = Controller flag = a for transmit data.
a = Command number x 2.
Machine ID : m = a for V8:
Step number a s = B - 99.
Data a seat as 36 bytes in 69 nibb1es;
low nibble first.
End of System Excluslve.
Page 2
NEW DATA AVAILABLE
Sent by VB when MX is on and a new Step or Program 15' called via
the front panel; or when the V8 leaves Edlt Mode'.
llllmufim status byte
Ellllill ID Number : l= 3; Octave-plateau
mpcccccc p = Controller flag a D for transmlt data.
c = Command number x a.
lllllllu End of System Exclusive.
LOAD ACKNOWLEDGE
Sent by VB when bulk program or step data is received. Allows
data handshake between VB and Computer controller.
zlxxoamo Status byte
21111111 ID Number I l = 3; Octave-plateau
fipcccccc p = Controller flag : B for transmit data.
' c = Command number I 12;
Ennnnnnn Program or Step number x n = o e 99.
11111116 End of System Exclusive.
EEQIE-lyéjelaejeselzsssex-_Qzesr;a_§..
NEW STEP
Causes specified STEP to be called if "X is on.
llllflflma Status byte
01111111 ID Number 3 i = 3; Octave-plateau
apcccccc p = Controller flag 1 G.
c = Command number s 9.
05555555 5 a Step number : a - 99.
11111118 End of System Exclusive.
BULK DATA FOR 1 PROGRAM
Loaded into V8 Program memory if MX is on and byte 3 controller
flag = 1. and Memory protect is off. Program scratch buffers may
be loaded when Memory Protect is on.
1111BBQB Status byte
21111111 ID Number 3 i = 3; Dctave~plateau
chccccc p = Controller flag : a = ignore data
1 a load data
c = Command number x 1.
Ommmmmmm Machine ID I m = B for V8.
Bppppppp Program number = p = B ~ 99.
126 Right scratch bu¥fer
127 Leit scratch butter
Emmmdddd Data 1 received as 45 bytes in 90 nibbles;
low nibble first.
1111111O End of System Exclusive.