Service Information S500i Circuit Change PROBLEM: It is possible that recently delivered S500I product has incorrect fuse type fitted . CAUSE: It is a fast blow instead of a slow blow time delay fuse which may be present. SOLUTION: To prevent premature fuse failure please change the incorrect fuse to the correct fuse. The current and voltage rating is the same. See below for correct type. Incorrect type - F250mA 250v or 250mA 250v Correct type - T250mA 250v (Time Delay/Slow Blow) Contact: NAD Electronics International 633 Granite Court Pickering, ON Canada L1K 3K1 Voice: 905-831-0799 FAX 905-837-6357 www.nadelectronics.com