Extracted text from Kenwood VR 409 Service Manual (Ocr-read)
Page 2
7 KRF7V7030D(K)COVER1,1P( 00.2.28 10:28 AM «by 2 +
KRF-V7030D/V8030D/VR-407/409
CONTENTS / ACCESSORIES
Contents
CONTENTS / ACCESSORIES .................................. 2 SCHEMATIC DIAGRAM .......................................... 17
BLOCK DIAGRAM ..... EXPLODED VIEW.
CIRCUIT DESCRIPTIO .. PARTS LIST ...........
ADJUSTMENT ........... ...11 SPECIFICATIONS .................................................... 51
PC BOARD .............................................................. 12
Accessories
FM indoor antenna (1) AM loop antenna (1) AC plug adaptor (1)
(T90'0836'05) (T90'0852'05I IE03'01 1505) Use to adapt the plug on the power cord
a i to the shape of the wall outlet.
I (Accessory only for regions where use is
necessary.)
Remote control unit (1) Batteries (RS/AA) (2) Remote control unit (1) Batteries (RS/AA) (2)
RC- R0609/R0610 RC-R0808/0809
W ,7 7 *0 ,/ o o
,nuooo®nunn «EDD-EQBUQCCCOOO .
\-D/I V lElgziiéz°89®t888888
Model name vs remote controller
Remote Controller
MODEL Destinations Parts number Model name Battery cover
r\
\/
VR-407 K A70-1330-05 RC-R0609 A09-1178-08
VR-407 P A70-1330-05 RC-R0609 A09-1178-08
KRF-V7030D Y A70-1330-05 RC-R0609 A09-1178-08
KRF-V7030D-S M A70-1330-05 RC-R0609 A09-1178-08
KRF-V7030D-S | A70-1330-05 RC-R0609 A09-1178-08
KRF-V7030D-S X A70-1330-05 RC-R0609 A09-1178-08
VR-407-S K1 A70-1330-05 RC-R0609 A09-1178-O8
VR-409 K A70-1315-05 RC-R0809 A09-1166-O8
VR-409 P A70-1315-05 RC-R0809 A09-1166-08
KRF-V8030D Y A70-1315-05 RC-R0809 A09-1166-08
KRF-V8030D-S M A70-1315-05 RC-R0809 A09-1166-08
KRF-V8030D-S | A70-1315-05 RC-R0809 A09-1166-08
KRF-V8030D-S X A70-1315-05 RC-R0809 AOQ-1166-08
KRF-V8030D E A70-1345-05 RC-R0808 A09-1166-08
KRF-V7030D E1 A70-1331-05 RC-R0610 A09-1178-08
KRF-V7030D T A70-1331-05 RC-R0610 A09-1178-08
Cautions
Resetting the Microcomputer
If the microcomputer may malfunction (unit cannot be operated, For U'S'A' and Canada
or shows an erroneous display) II the power cord IS unplugged Unplug the power cord tram the wall outlet, then plug it back in
while the power is ON, or due to some other external factor. If while holding down the POWER key.
this happens, execute the following procedure to reset the
microcomputer and return the unit to its normal operating
condition. For other countries
With the power cord plugged in, turn the POWEFt key OFF. Then,
' ' '|| | th
Please note that resetting the microcomputer WI 0 ear e contents while holding down the ON/STANDBV key, press POWER.
of the memory and returns the unit to the state it was in when it left
th e factory.
l l 4