Jvc RMLP 57 Service Manual

This is the 25 pages manual for Jvc RMLP 57 Service Manual.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.

Page: 1 / 25
Jvc RMLP 57 Service Manual

Extracted text from Jvc RMLP 57 Service Manual (Ocr-read)


Page 2

JVC

Instructions

REMOTE CONTROL UNIT RM-LP57

BEDIENUNGSANLEITUNG:
FERNEEDIENEINHEIT

MANUEL DINSTRUCTIONS:
UNITE DE TELECOMMANDE

For Customer Use:
Enter below the Serial No. which is located
on the rear of the body.
Retain "'IIS information tor tuture reterance.

Model No. RM-LP57
Senal No.

a? CAUTION @
osmium

WARNING:
To PREVENT FIRE OR SHOCK HAZARD, DO NOT
EXPOSE THIS UNIT TO RAIN OR MOISTURE.

(JUTION. TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK),
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

AVEHTISSEMENT:

FOUR EVITEH LES RISOUES D'INCENDIE 0U
D'ELECTROCUTION, NE PAS EXPOSER L'APPAREIL
A L'HUMIDITE 0U A LA PLUIE.

The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulatd "dangerous voltage" within
the product's enclosure that may be sufficient magni-
tude to constitute a risk of electric shock to persons.

Information for USA

This device complies with Part 15 ot the FCC Rules.
Changes or modifications not approved by the original
manutacture could void the users authority to operate the
equipment.

The exclamation point within a equilateral triangle is

intended to alert the user to the presence of important
operating and maintenance (servicing) instIUCtions in
the literature accompanying the appliance,

Due to designmoditications, data given in this instruction
book are subject to possible change without prior notice

POWER SYSTEM

Connection of power supply.
The RM-LP57 is designed for connection to the model KY-

lntormatlon for CANADA

This digital apparatus does not exceed the Class B Limits
lor radio noise emissions from digital apparatus as set out
in the interference causing equipment standard entitled
'Digital Apparatus", ICES-003 of the Department oi
Communications.

Reneelgnement pour CANADA
Cet appareil numérique respects Ies Iimites de bruits
radioelectriques applicables aux appareils numériques de
Class B prescrites dans la norme sur la materiel
brouilleur; Appareils Numériques', NMB-Ooa édictée par
le ministre des Communications.

F558, KY-F50 and KY-F32 Color Video Camera.

Power is supplied trom the video camera.

Changes or modifications not approved by JVC could void
the users authority to operate the equipment.

Page 5

CONTROLS, CONNECTORS AND INDICATORS

0 [SHUTTER]
The cameras Shutter mode can be set with the 7-posr-
tion shutter mode switch. (NORMAL, 1/100 or 1/120.
1/250, 1/500, 1/1000, 1/2000, EEI)

Note:
- When the sensitivity switch is set to ALC+EEI, the
Shutter mode is locked to EEI regardless ol the
shutter mode switch position.
- When the shutter mode switch is set to EEI, the
cameras iris is set to auto iris regardless oi the
position of the iris mode switch.

0 [WHITE PAINT]

When the White Balance mode is set to AUTO1 or
AUT02, gain for the R or B channels can be tine-adjusted
with the white paint control,

- When the white paint controls are set to the center
positions, the white balance condition obtained with
the auto white balance tunction has priority.

- To activate the paint tunction alter completion ol
auto white balance operation, set the white paint
controls to positions other than center. If this is not
necessary, leave the white paint controls at the
center position.

- The previous settings ol the white paint controls are
stored in memory so you can obtain the same con-
dition when the power is supplied again even it the
control positions have been changed. When you
turn the controls, the stored settings are canceled
and the current settings become etfective.

0 [TO RM-713MD] 7-pin connector
Connect the RM-713MD remote control unit (optional).

03 [Cable holder]
Use to secure the cables connected to the RM-713MD.

OD [Cable] 5m
Connects the remote control unit to a camera.

OPERATIONS

1. Connect RMALP57 to the camera as described in CON-
NECTIONS". (Page 3)

. Turn the camera's power unit ON. (For camera opera
tion, reler to the camera's instruction manual.)

2
3. Press the FlM-LPS? OPERATE switch to ON.
4

. The OPERATE LED blinks. then lights up, indicating
that remote operation with the FlM-LP57 is now possi-
ble.

- After the power is switched on, initialization of the RM-
LP57 takes about two seconds. Operation is not possi-
ble during this time.

0 [IRIS]
Manual iris (MANUAL) or auto iris (AUTO) can be select-
ed with the iris mode switch.

AUTO

:The auto iris level can be adjusted with the
iris control knob.

Note:

- When the LENS switch is set to MANU, the auto iris
lunction does not operate even it the AUTO mode
is selected.

MANUAL :The iris can be adjusted lrorn CLOSE to
OPEN with the iris control knob.
Note:
- The Auto Iris mode is automatically engaged when-
ever the sensitivity switch is set to ALC or
ALC+EEI, or the shutter mode switch is set to EEl.
Manual operation is not possible.
-The iris may not close completely with some lens»
as.

([9 [MASTER BLACK]
The black level can be adjusted with the master black
control.

- The standard position of the master black control is
the center position.

USING AN MD LENS

The optional FlM-713MD lens remote control unit is required
when using an MD lens.

0 Control of the locus, zoom and iris 01 an MD lens (HZ-
610MD) is possible when the RM-713MD lens remote
control unit is connected to the FlM-LP57.

Note:

' The zoom and focus cannot be controlled if the lens
is not an MD lens.

- When using a power unit other than the AA»P700 to
power the camera when the RM-713MD, is con
nected, the power unit must supply 115 V to 13 V.
1 A or more.

Connection

1. Remove the two screws on the panel of the RM-713MD
to remove the case from the control panel.
. Remove the case of the RM-713MD.

Case

Remove

m