Harman kardon td 212 service manual

This is the 40 pages manual for harman kardon td 212 service manual.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.

Page: 1 / 40
harman kardon td 212 service manual

Extracted text from harman kardon td 212 service manual (Ocr-read)


Page 1

The Harman Kardon
MOdel TD212 Manual 124A

ULTRAWIDEBAND UNEAR PHASE CASSETTE DECK

T@©[hmfi@@fl {Mammal

The following mark found in the parts list of this manual identify
the model as follows.
GD : General model Black version

aizcu /

harman/kardon

240 Crossways Park West, Woodbury, N.Y. 11797
1112-3152124A8 P4178801 1500 Primed in Japan

\W wrfl,mwflxwwa_www -.

Page 2

SPECIFICATIONS

Nominal Limit

Nominal Lim it

Track Configuration 4-track 2 Channel Stereo Channel Separation 45 d8235 dB
Cassette Deck Crosstalk 70 dB 2 60 dB
OMECHANICAL SECHON Record/Playback Distortion
Record/Playback Tape Speed "le 1 kHz)
Deviation 4.7Scm/sec. 0.05% i 1.5% LN 13% S 20%
Drift 4.75cm/sec. 0.2% i 2.0% 0° "3% S 39%
Wow and Flutter 0.05% (NAB) _<_ 0.1% . .mea' 15% S 2'0""
0.008% (CCIR) MPX Filter Attenuation
Take Up Torque 509mm 35 ~ 70gr.cm at 15 kHz 0'3 dB 51 63
Back Tension 4gr.cm 2 ~ Ggr.cm . at 19 kHz 35 dB 2 30 dB
F. FWD Torque 1009mm 70~1509r.cm 5 Rm "9 8° 2
REW Torque 1009mm 70~150§r.cm LN 7° dB 2 6 B
F. FWD/REW Time as sec. 2 100 sec. . . . Mm' 5 d3 3 5? 3
(060 Tape) Input Sensmvrty . 52 mV40(mln)~10IJ(max)mV
Motor Direct Drive Motor an 1 kHz) at "9 Input

Input Impedance
(Input 1kHz) at Line Input

23 kn 19(min) ~30(max) k0
.AMPLIFIER SECTION

Bias Frequency 105 kHli 5 kHz ODIMENSIONS (W x H x D) 17~3/8" x 443/16" x 9-1116"
Playback Output 480mV i1.5d8 (443 x 122 x 230 mm)
Slgnal:to-Noise Ratio OWEIGHT 8.5le (3.9kg)
(alt LIne1IE'EZut 00 V) OPOWER SUPPLY
nput , 1 m
IHF-A WTD at Dolby Level U.S.A. & Canada models AC120V, 60H:
General model AC220V/240V
, Dolby NFl off
LN 51" oPowen CONSUMPTION 50/sz
Cr02 54dB
Metal 54dB U.S.A. & Canada models 18W
Dolby B NR General model 20W
LN 61 dB

CrOz 64 dB 2 60 (13

Metal 64dB 260 dB
Dolby C NR

LN 66 dB

CrOz 70 dB 2 66 113

Metal 70 dB 2 66 dB

LEAKAGE TEST (FOR SERVICE ENGINEERS IN THE U.S.A.I

These specifications are service target specs.

Specifications and components are subject to change without notice.
Overall performance will be maintained or improved.

Before returning the unit to the user, perform the following safety checks:
1. Inspect all lead dress to make certain

that leads are not pinched or that SIMPSON MODEL 229 ETC. FOR

hardware is not lodged between the LEAKAGE 51

eheeehe ehe ehheh meeeh he he assesses: ._®_. 12 massacre

unit. UNIT UNDER TEST ".5 ceouno ex CABLEtCONDUIT, ETC.
2. Replace all protective devices such XELIQEED LEAD

as nonmetallic control knobs, in-

sulating fishpapers, cabinet backs,

adjustment and compartment covers

or shields, isolation resistor- S

capacitor networks, mechanical in- VTVM

sulators, etc. -0 Ac SCALE 0-
3. Be sure that no shock hazard exists; check for leakage current

using Simpson Model 229 Leakage Tester, standard equipment

item No. 21641, RCA Model WT540A or use alternate method as

follows:
Plug the AC line cord directly into a 120-volt AC receptacle (do not
use an Isolation Transformer for this test). Using two clip leads,
connect a 1500 ohm, 10-watt resistor paralleled by a 0.15yF
capacitor, in series with all exposed metal cabinet parts and a
known earth ground, such as a water pipe or conduit. Use a VTVM
or VOM with 1000 ohms per volt, or higher sensitivity to measure
the AC voltage drop across the resistor. (See Diagram.) Move the
resistor connection to each exposed metal part having a return path
to the chassis (antenna, metal, cabinet, screw heads, knobs and control shafts, escutcheon, etc.) and measure the AC voltage
drop across the resistor. (This test should be performed with the power switch in both the On and Off positions.)
A reading of 0.35 volt RMS ormore is excessive and indicates a potential shock hazard which must be corrected before
returning the unit to the owner.

LSKOHM
IDW

TD212

TEST PROBE

T0 EXPOSED
METAL PARTS

CONNECT TO KNOWN