Harman kardon pm 655 vxi service manual

This is the 38 pages manual for harman kardon pm 655 vxi service manual.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.

Page: 1 / 38
harman kardon pm 655 vxi service manual

Extracted text from harman kardon pm 655 vxi service manual (Ocr-read)


Page 1

The Harman Kardon
Model PM655 in g,

ULTRAWIDEBAND INTEGRATED AMPLIFIER

Tedmficeal Mandel

my mum. mm mm... W9-

The following marks found in the parts list of this manual idenfify
the models as follows.

an : North America area model

(3!. : North America area model Black version

0 : General model

(fiz) : General model Black version

0 : Japan model

harman/kardon

240 Crossways Park Wesf,Woodburv4 N.Y,11797
lll2-3152116AO FVOSSHO 3500 Primed In Japan

M 999m f 1

Page 2

W i

SPECIFICATIONS
Nominal Limit Nominal Limit
RMS Output Power Filters
89, 1kHz THD o_os% 107W290W Subsonic 15Hz, - 3dB: ldB/Octave
4n, 1kHz THD 0.1% 11ewggow High Cut 6kHz, -3dB:1dB/0ctave /
High Instantaneous Current DC OUtPUt Voltage (
Capability (HCCI 47A g4OA L channel OmV 1 60mV _,
Half Power Bandwith 10Hz ~100kHz Fl channel OmV : 60mV
Frequency Responce at - 3dB O.15Hz~180kHz RlAA Equalization at Tape OUt
Input Sensitivity (20Hz/20kHz) (No load) 0.2dB:l_'0.5dB/-0.1dBiO.5dB
Video/CD, Tuner 135mV I 25mv Phono Over Load (No load)
Phono (MM) 2.2mv:o.3mv* Phono IMMI 220mV2190mV
Phono (MC) V 120pV 1 20;;V * Phono (MC) 12. 2mV g 8mV
Signal to Noise Ratio Dimensions (W X H X D) 171/2" X 5-5/16 x 15-11/16
Video/CD, Tuner 78ng 75dB (443 x 134 x 398mm)
Phono (MM) 78ng73dB Weight 22lbs. 1102. (10.3kg)
Phono (MC) 77.5ng74dB Power Supplies
Channel Separation at 10kHz North America area model AC 120V, 60Hz
Video/CD 59de45dB General model AC 220/24OV, 50/60Hz
Phono (MM), Tuner 59dBi4sdB Japan model AC 100V, 50/60Hz
Phono (MC) 63dB 544w; Power Consumption
IM Distrotion Ratio 0,07%§o_13% North America area model 340W (34OVA)
Damping Factor at lkHz 71 g 50 General model 230W
Tone Control Characteristics Japan model 340W

Bass Turnover Frquencyl200Hz/4OOHZ)
>1 Bass at 50Hz/1OOH2
. Boost 10mg: 2dB * Input Sensitivity for General model are 2.2mV i 0.3mV
. I Cut 10dB:2dB (MM) and 140uV: ZOMV (MC).
Treble Turnover Frquency (2kHz/6kHz)
Treble at 10kHz/30kHz

Boost 1odBi 2dB This specification is the target oi servicing. But, there is a care that the
Cut 10dB + 2dB specification is not applicable to the measurement condition and instrument.

Specifications and components subject to change without notice. Overall
performance will be maintained or improved.

LEAKAGE TEST (FOR SERVICE ENGINEERS IN THE U.S.A.l

Before returning the unit to the user, perform the following safety checks:
1. Inspect all lead dress to make certain

that leads are not pinched or that SIMPSON MODEL 229 ETC. FOR
hardware is not lodged between LEAKAGE TEST
the chassis and other metal parts

TO AC GROUND SUCH V __
AS WATER PIPEBX CABLE, é
CONDUIT, ETC. _


in the unit, . TO EACH EXPOSED
2. Be sure that any protective devices Mfilfibrsgggéégtgp HIGH
such as nonmetalllc control knobs, VOLTAGE
insulating fishpapers, cabinet backs, OH + LEAD
adjustment and compartment covers
or shields, isolation resistor-capacity
networks, mechanical insulators, 6
etc. which were removed for servic-
ing are properly reinstalled. VTVM
3. Be sure that no shock hazard exists; check for leakage -0 AC SCALEO-
current using Simpson Model 229 Leakage Tester,
. standard equipment item No. 21641, RCA Model 1.5m
' WT540A or use alternate method as follows: 0"
Plug the power cord directly into a 120-volt AC _.._W\,_
receptacle (do not use an Isolation Transformer for
this test). Using two clip leads, connect a 1500
Ohm, 'IO-watt resistor paralleled by a 0.15 er capacitor, I I
in series with all exposed metal cabinet parts and
a known earth ground, such as a water pipe or conduit.
Use a VTVM or VOM with 1000 Ohms per volt, or g
higher sensitivity to measure the AC voltage drop TEST PROBE (
across the resistor. (See Diagram.) Move the resistor "i
connection to each exposed metal part having a
return path to the chassis (antenna, metal, cabinet, T0 EXPOSED CONNECT T0 KNOWN
screw heads, knobs and control shafts, escutcheon, METAL PARTS EARTH GROUND
etc.) and measure the AC voltage drop across the
resistor. (This test should be performed with the power switch in both the On and Off positions.)
A reading of 035 volt RMS or more is excessive and indicates a potential shock hazard which must be corrected
before returning the unit to the owner.

X.

LEAD

0.15uF

PM655 in