Harman kardon hk 880 vxi service manual
This is the 48 pages manual for harman kardon hk 880 vxi service manual.
Read or download the pdf for free. If you want to contribute, please upload pdfs to audioservicemanuals.wetransfer.com.
Extracted text from harman kardon hk 880 vxi service manual (Ocr-read)
Page 1
The Harman Kardon
Model hk880in
HIGH VOLTAGE/ HIGH CURRENT
STEREO RECEIVER
Teeimmiceal Mammal
1101'!
a I:l I:- E!
D©e® (H) CH.) (E) (U) (H) Qa
1=I El
The following marks found in the parts list of this manual identify
the models as follows.
: North America area model
: North America area model Black version
: General model
: General model Black version
: Australia model Black version
eeeee
harman/kardon
240 Crossways Park West, Woodbury, N.Y. 11797
1112-3152134Aa P078803 1500 Printed in Japan
!XI\089)lll
Page 2
hk880in
SPECIFICATIONS
OFM SECTION
Tuning Range
50dB Ouieting Sensitivity
Mono
Stereo
Usable Sensitivity
Image Ratio
IF Rejection
Spurious Response Rejection
Capture Ratio
Alternate Channel Selectivity
AM Rejection
Signal to Noise Ratio
Mono
Stereo
Total Harmonic
l65dBf 1kHz Input)
Mono
Stereo
Stereo Separation at 1kHz
0AM SECTION
Tuning Range
North America area model
General and Australia models
Usable Sensitivity
Selectivity
Signal to Noise Ratio
Image Rejection
IF Rejection
.AUDIO SECTION
Usable Sensitivity
Video/CD
Phono
Signal to Noise Ratio
Video/CD
Phone
Channel Separation at 10kHz
Video/CD
Phono
Distortion
Nominal Limit
87.5 ~ 108.0MHZ
15.2dBf é 19dBl
37dBf é 41dBf
10.7dBf é ISdBf
75dB ; 60dB
100dB g 85:13
100dB g 85dB
1.5dB é 2.5dB
70dB 2 60:13
54.5dB g 45dB
80dB
E 74dE
73.5dB g
70dB
0.08%
0.08%
53dB
0.3%
0.3%
45:15
IN A IIA
520 ~
531 ~
1,620kH1
1,602kHz
16 me § 40 #Vm
32dEI g 25dE
53dB 2 48dB
40dB g 32dB
62dB ; 50dB
135mV i 25mV
2.2mV i 0.2mV
SldB 2 75d8
79.5dB 2 73dB
52.5dB 2 45dB
56:13 2 45dB
IM Distortion Ratio
RMS Output Power
8.0, 1kHz, THD 0.1%
4.0, 1kHz, THD 0.3%
Damping Factor at lkHz
Tone Control Characteristics
Bass at 50H:
Boost
Cut
Treble at 10kHz
Boost
Cut
Loudness Control
at IDkHz
at SOHz
Subsonic Control
at 15Hz
DC Output Voltage
L channel
R channel
Nominal Limit
0.06% § 0.015%
77.5w 3 60W
123.2W E 60W
58 g 50
10dB i 2dB
~10dB i ZdB
10dB i ZdB
-10dB i ZdB
SdB +
_ 1dB
10dB i
ZdB
-3.5dB i 1.5dB
BmV i 60mV
5mV i GOmV
RIAA Equalization at Tape Out (20Hz/20kHz)
D.D7dBi0.5dBID.28dBi0.5dB
ODIMENSIONS (W x H x D)
17-3/8" x 5-1/4" x 14-1/2
(443 x 134 x 368 mm)
oWEIGHT
oPOWER SUPPLV
North America area modal
General and Australia models
OPOWER CONSUMPTION
North America area model
General and Australia models
22 lbs. (10 kg)
AC120V, 60Hz
AC220/24DV, 50/60HZ
280W l340VAl
210W
These specifications are Service target specs.
Specifications and components subject to change without notice.
Overall performance wlll be malntalned or Improved.
LEAKAGE TEST (FOR SERVICE ENGINEERS IN THE U.S.A.)
Before returning the unit to the user. perform the following safety checks:
1. Inspect all lead dress to make certain
that leads are not plnched or that
hardware is not lodged between the
chassis and other metal parts in the
unit.
2. Replace all protective devices such
as nonmetallic control knobs, in-
sulating fishpapers, cabinet backs,
adjustment and compartment covers
or shields, isolation resistor-
capacitor networks, mechanical in-
sulators, etc.
3. Be sure that no shock hazard exists; check for leakage current
using Simpson Model 229 Leakage Tester. standard equipment
item No. 21641, RCA Model WT540A or use alternate method as
follows:
Plug the AC line cord directly into a 120-volt AC receptacle (do not
use an Isolation Transformer for this test). Using two clip leads,
connect a 1500 ohm, 10-watt resistor paralleled by a 0.15,uF
capacitor, in series with all exposed metal cabinet parts and a
known earth ground, such as a water pipe or conduit. Use a VTVM
or VOM with 1000 ohms per volt, or higher sensitivity to measure
TO EACH EXPOSED
METAL SURFACE OF
UNIT UNDER TEST
HIGH
VOLTAGE
n
LEAKAGE TEST
SIMPSON MODEL 229 ETC. FOR
T0 AC GROUND SUCH
AS WATER OR GAS PIPE.
GROUND EX CABLECONDUIT, ETC.
TO E XPOSE D
METAL PARTS
TEST PROBE
LEAD
é
VTVM
'0 AC SCALE 0'
1.5 K OHM
10W
CONNECT TO KNOWN
EARTH GROUND
the AC voltage drop across the resistor. (See Diagram.) Move the resistor connection to each exposed metal part having a
return path to the chassis (antenna, metal, cabinet, screw heads, knobs and control shafts, escutcheon, etc.) and measure the
AC voltage drop across the resistor. (This test should be performed with the power switch in both the On and Off positions.)
A reading of 0.35 volt RMS or more is excessive and indicates a potential shock hazard which must be corrected before
returning the unit to the owner.