Page 1

SAFETY INSTRUCTIONS Read instructions - All the safety and operating instruc- tions should be read before the appliance is operated. Retain instructions - The safety and operating instructions should be retained for future reference. Heed warnings - All warnings on the appliance and in the operating instructions should be adhered to. Follow instructions - All operating and use instructions should be followed. Water and Moisture - The appliance should not be used near water - for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, and the like. Carts and Stands - The appliance should be used only with a cart or stand that is recommended by the manufac- turer. An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to over- turn. Wall or Ceiling Mounting - The appliance should be mounted to a wall or ceiling only as recommended by the manufacturer. Ventilation - The appliance should be situated so that its location or position does not interfere with its proper ven- tilation. For example, the appliance should not be situ- ated on a bed, sofa, rug, or similar surface that may block the ventilation openings; or, placed in a built-in installa- tion, such as a bookcase or cabinet that may impede the flow of air through the ventilation openings.Heat - The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat. Power Sources - The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance. Grounding or Polarization - The precautions that should be taken so that the grounding or polarization means of an appliance is not defeated. Power Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience recep- tacles, and the point where they exit from the appliance. Cleaning - The appliance should be cleaned only as rec- ommended by the manufacturer. Nonuse Periods - The power cord of the appliance should be unplugged from the outlet when left unused for a long period of time. Object and Liquid Entry - Care should be taken so that objects do not fall and liquids are not spilled into the en- closure through openings. Damage requiring Service - The appliance should be ser- viced by qualified service personnel when: A. B. C. D. E. Servicing - The user should not attempt to service the ap- pliance beyond that described in the operating instruc- tions. All other servicing should be referred to qualified service personnel. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT. POUR ÉVITER LES CHOCS ÉLECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRE- SPONDANTE DE LA PRISE ET POUSSER JUSQU' AU FOND. CAUTION: ATTENTION: The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and mainte- nance (servicing) instructions in the literature accompanying the appliance. The lightening flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated dangerous voltage within the product's en- closure that may be of sufficient magnitude to constitute a risk of electric shock to persons. WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOIS- TURE. 1. 2. 3. 4. 5. 6. 7. 8.The power supply cord or the plug has been damaged; or Objects have fallen, or liquid has been spilled into the appliance; or The appliance has been exposed to rain; or The appliance does not appear to operate normally or exhibits a marked changed in performance; or The appliance has been dropped, or the enclosure damaged. 9. 10. 11. 12. 13. 14. 15. 16. 17. 7 COP-1/96kCOP-1/96k 4. CIRCUIT & BLOCK DIAGRAMS 1 3 2 U3 GPIF37R1 OPTICAL IN D+5 DGND R6 47K C13 0.1 DGND R3 330 R2 2.2KU2C 74HCU04 D+5 DGND 1 3 2 U4 GPIF38T2OPT_RX C16 NON (0.01) DGND C1 10/35 D1 DSK10C-BT 1 3 2 U1 78L05 IN OUT C12 0.1 D+5 VCC DGNDGND 346 1 2 K7-T T1 R4 75 L12 BEAD R9 470 D+9 DGNDD4 LED_G DC_INJ1 OPT_TX L2 jumper (W2) R1 3.3K C14 0.1 C3 10/3556 U2E 74HCU04 11 10 U2F 74HCU04 13 12 U2D 74HCU04 98 DGND L10 BEAD L13 BEAD CHASSISC15 0.1 J2 COAX_OUT COAXIAL OUT 74HCU04 U2A DGND R5 2.2K DGND C18 22P C19 47PR7 10 D2 GMA01 D3 GMA01 C17 NON (0.01) C5 33/25 R8 75 DGND L11 BEAD J3 COAX_IN DGND OPTICAL OUT CHASSIS L1 6 HOLE C11 0.1 C10 0.1G C2 10/35 COAXIAL IN U2B 74HCU04C4 33/25 1 21 2 43 21 COP-1/96k PCB

Page 2

3 6 COP-1/96kCOP-1/96k Parts marked with this sign are safety critical components. They must always be replaced with identical components. Refer to the Fostex Parts List and ensure exact replacement. CAUTIONTABLE OF CONTENTS Owner's manual : 8288455000 (for export model) : 8288456000 (for domestic model) AC adaptor AD-9A : 8270728003 (for USA/CND) : 8270728006 (for EUR) : 8270728007 (for UK) : 8270728010 (for JPN) Parts List and circuit diagrams are given in this manual to assist the service technician in maintaining the Model COP-1/96k. NOTES The following accessories are supplied with COP-1/96k as the standard accessories. * * Following is the packing material for the Model COP-1/96k. * Carton, inner, COP-1/96k : 8228691000 Packing, COP-1/96k : 8228409000 ! 1. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. CONTROLS, INDICATORS AND CONNECTORS . . . . . . . . . . . . 3. EXPLODED VIEW, PCB ASSEMBLY AND PARTS LIST . . . . . . 4. CIRCUIT & BLOCK DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . .4 4 5 7 ! Ref. No. Part No. Description 8274 0310 00 PCB Assy, COP-1/96k 8251 9471 01 Plain PCB, COP-1/96k ICs Ref. No. Part No. Description U001 8236 0220 00 92, AN, regulator, NJM78L05A U002 8236 0074 01 DIP, DG, CMOS, 74HCU04 U003 8245 5530 10 Connector, opt, GPIF37R1 U004 8245 5520 10 Connector, opt, GPIF38T2 DIODEs Ref. No. Part No. Description D001 8234 0162 02 V, DSK10C D002, 003 8234 0085 00 VF, GMA01-FY1, F5 D004 8234 0201 00 Opt., V, LED, grn, GL3KG8 RESISTORs Ref. No. Part No. Description R001 8230 0563 32 HF, carbon, 1/4W, 3.3kW, 5%, F5 R002 8230 0562 22 HF, carbon, 1/4W, 2.2kW, 5%, F5 R003 8230 0563 31 HF, carbon, 1/4W, 330W, 5%, F5 R004 8230 0567 50 HF, carbon, 1/4W, 75W, 5%, F5 R005 8230 0562 22 HF, carbon, 1/4W, 2.2kW, 5%, F5 R006 8230 0564 73 HF, carbon, 1/4W, 47kW, 5%, F5 R007 8230 0561 00 HF, carbon, 1/4W, 10W, 5%, F5 R008 8230 0567 50 HF, carbon, 1/4W, 75W, 5%, F5 - COP-1 PCB assy COP-1/96k Parts List Ref. No. Part No. Description R009 8230 0564 71 HF, carbon, 1/4W, 470W, 5%, F5 CAPACITORs ALU = Electrolytic type CER = Ceramic type Ref. No. Part No. Description C001~003 8232 0971 06 V, ALU, 35V, 10µF, 20%, SME-VB C004, 005 8232 0953 36 V, ALU, 25V, 33µF, 20 %, SME-VB C010~015 8232 8041 04 V, CER, 25V, 0.1µF, +80-20 %, YF C016, 017 N/A C018 8232 0502 20 V, CER, 50V, 22pF, 5%, SL C019 8232 0504 70 V, CER, 50V, 47pF, 5%, SL C020 8232 8041 04 V, CER, 25V, 0.1µF, +80-20 %, YF MISCELLANEOUS Ref. No. Part No. Description Y201 8276 8730 02 Tube, UL, black, 1, L05 E201 8276 0020 02 Wire, jumper, F5 E202 8276 0020 04 Wire, jumper, F10 J001 8245 5440 00Connector, jack, DC inlet, YKB31-0014 J002, 003 8245 2460 10 Connector, PL, jack, RCA, 1P, EMI, WP371 L001 8242 1350 01 Filter, EMI, 6 hole L002 8276 0020 04 Wire, jumper, F10 L010~013 8242 1860 13 Filer, T, EMI, LFW7B-M3R2T T001 8242 2350 00 Transformer, digital out, K7-T COP-1/96k PCB Pattern drawing C13C19R1 R3 R2 R5 C3L2 + C1 L12 C5 C17 C20R7 R6 + + + R9 C10 D3 U1 L10 C15 D4 J1 J2C16 C4 L1D2 R4D1 C11 C18 U4 C14U3 U2 + T1 L11 R8 L13 J3 COP-18251947 101 Designd by HARUMI.A C2 C12